INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE

치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향

  • Yang, Jeong-Ok (Department of Conservative Dentistry, School of Dentistry Kyungpook National University) ;
  • Kim, Sung-Kyo (Department of Conservative Dentistry, School of Dentistry Kyungpook National University) ;
  • Kwon, Tae-Kyung (Department of Conservative Dentistry, School of Dentistry Kyungpook National University)
  • 양정옥 (경북대학교 치과대학 보존학교실) ;
  • 김성교 (경북대학교 치과대학 보존학교실) ;
  • 권태경 (경북대학교 치과대학 보존학교실)
  • Published : 1998.12.04

Abstract

The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

본 연구의 목적은 미세치근단 수술법에서 사용되는 치근단 절제방법 및 역충전와동 술식을 종래의 치근단 수술법에서 사용해 온 술식 및 방법과 치근단 미세누출의 측면에서 비교, 연구하고자 함이다. 치근단 절제방법 및 역충전와동 형성 방법에 따른 치근단 누출을 평가하기 위해서는 최근에 발거된 상악 중절치, 측절치 및 견치 71개를 절제 각도 및 와동 형성방법에 따라 5개의 군으로 분류하여 실험하였으며, 근관협부 처리에 따른 치근단 누출을 평가하기 위해서는 최근 발거된 상악 제 1대구치의 근심협측 치근 44개를 근관협부의 처리 유무에 따라 2개군으로 분류하여 실험하였다. 각 시편치아에서 근관을 형성하고 측방가압법으로 충전한 후 각 군에 따라 저속 다이아몬드 절단기를 이용하여 치근단 3 mm를 절제하였으며 저속 round bur와 초음파 스테인레스 스틸 기구를 이용하여 역충전와동을 형성하고 IRM으로 역충전하였다. 시편을 2% methylene blue 용액에 7일간 침잠시킨 후 35% 질산 용액에서 용해시킨 다음, 원심분리한 상층액을 비색계를 이용하여 누출 색소의 홉광도를 측정하였다. 결과치는 이원변량분석법과 Duncan's Multiple Range Test를 이용하여 분석하였으며, 다음과 같은 결과를 얻었다. ${\cdot}$ 사면을 부여하지 않고 치아 장축에 대해 직각이 되게 치근단을 절제하고 치아 장축에 평행하게 역충전와동을 형성한 경우, 초음파기구를 이용한 군과 저속 round bur를 이용한 군사이에는 미세누출에 있어서 유의한 차이가 나타나지 않았다(p>0.05). ${\cdot}$ 사면을 부여하면서 치근단을 절제하고 치아 장축에 평행하게 역충전와동을 형성한 경우, 초음파기구를 이용한 군은 저속 round bur를 이용한 군에 비해 유의하게 적은 치근단 누출을 보였다(p<0.0001). ${\cdot}$ 초음파기구를 이용하여 역충전와동을 형성한 경우에는, 치근단 절제시 사면의 부여에 관계없이 치근단 누출에 유의한 차이가 나타나지 않았으나(p>0.05), 저속 round bur를 이용한 경우에는, 사변을 형성하지 않은 군이 사면을 형성한 군에 비해 유의하게 적은 미세누출을 나타내었다(p<0.0001). ${\cdot}$ 치근단 절제시 사변을 부여한 경우에는, 저속 round bur로 치아 장축에 평행하게 역충전와동을 형성한 군은 치아 장축에 직각으로 역충전와동을 형성한 군에 비해 미세누출이 적게 나타났지만, 유의한 차이는 나타나지 않았다(p>0.05). ${\cdot}$ 초음파 기구를 이용하여 근관협부를 따라 역충전 와동을 형성한 군은 저속 round bur를 이용하여 근관협부를 따라 역충전 와동을 형성하지 못한 군에 비해 유의하게 적은 치근단 누출을 나타내었다(p<0.0001).

Keywords