Abstract
This research aims to develop an algorithm of optimal transducer placement for health monitoring of large structural system. The structural vibration response-based health monitoring is considered one of the best for the system which requires a long-term, continuous monitoring. In its experimental modal testing, however, it is difficult to decide on the measurement locations and their number, especially for complex structures, which have a major influence on the quality of the results. In order to minimize the number of sensing operations and optimize the transducer location while maximizing the accuracy of results, this paper discusses about an optimum transducer placement criterion suitable for the identification of structural damage for continuous health monitoring. As a criterion algorithm, it proposes the Kinetic Energy Optimization Technique (EOT), and then addresses the numerical issues which are subsequently applicable to actual experiment where a bridge model is used. By using the experimental data, it compares the EOT with the EIM(Effective Indefence Method) which is generally used to optimize the transducer placement for the damage identification and control purposes. The comparison conclusively shows that the EOT algorithm proposed in this paper is preferable when a structure is to be instrumented with fewer sensors for monitoring purpose.
이 연구의 목적은 대형 구조물의 상설 감지를 위한 감지기의 최적 위치의 알고리즘을 개발하는데에 있다. 구조물의 진동을 이용한 감지 시스템은 장기적으로 계속해서 구조물을 자동으로 감지하는데에 좋은 방법중의 하나이다. 하지만 구조물의 진동을 정확히 계측하기 위해서는 감지기의 위치나 감지기의 숫자에 큰 영향을 받는데, 이와 같은 일은 대형 구조물에 있어서 쉽지가 않다. 최적의 감지기 위치와 최소의 감지기로 가장 정확한 데이터를 획득하기 위하여 최적합한 감지기의 위치를 위한 알고리즘이 개발되어 수치적 그리고 실험적으로 유용성을 보인다. EOT가 개발되어 모형 교량에 적용하여 EIM과 비교 분석된다. 이들의 비교를 통하여, 이 연구에서 제안되어진 EOT가 적은 수의 감지기로 좋은 결과를 보여, 상설감지의 목적에 적합함을 보여준다.