대한치과보철학회지 (The Journal of Korean Academy of Prosthodontics)
- 제34권4호
- /
- Pages.746-754
- /
- 1996
- /
- 0301-2875(pISSN)
- /
- 2005-3789(eISSN)
Porcelain Laminate veneer 절연 피복시 설측 연장 길이에 따른 파절강도의 연구
THE STUDY OF FRACTURE STRENGTH OF PORCELAIN LAMINATE VENEER WITH VARIOUS LINGUAL EXTENTION LENGTH WHEN LNCISAL RESTORING
- Park, Johng-Han (Department of Prosthontic, College of Dentistry, Kyungpook National University) ;
- Jo, Kwang-Hun (Department of Prosthontic, College of Dentistry, Kyungpook National University)
- 발행 : 1996.12.01
초록
개교증, 절연부 파절, 변색등 심미적 요인으로 라미네이트를 설측연장시 연장길이에 따른 파절강도를 알아보기위해 발거된 60개의 상악 전치의 순면에 3개의 seating form을 형성하고sheet wax를 사용하여 가로 5mm
The purpose of this study was to evaluate the fracture strength of porcelain laminate veneer with various lingual extention length when incisal restoring. Sixty recently extracted, intact maxillary incisors were used and stored in a physiologic saline solution from the time of extraction. Seating form was preparation at the labial surface of each tooth with a water-cooled round diamond bur. Standard block was formed with 32 gauge and 24 gauge wax at tooth labial and lingual surface. Lingual extention length differed according to each group. (group I : 0.5mm, group II : 1 mm, group III : 2mm, group IV : 0mm) All tooth specimens were impressioned with examix(GC Inc., Japan). Refractory cast were maked with refractory die material(Ceramco Inc., U.S.A.) Laminate porcelain (Ceramco II Veneer porcelain, Ceramco Inc., U.S.A.) was condensed in refractory die cast and baked according to the manufacturer's recommendations. Each surface was contoured with low speed diamond bur according to guide block. All porcelain specimens were sandblasted and ultrasonically cleaned in distlled water for 3 minutes. Then, all porcelain specimen were etched with 8% hydrofluoric acid for 5 minutes. Sixty specimens were bonded with composite resin cement(Choice Porcelain Veneer System, Bisco Inc., U.S.A.) according to manufacture's directions. The fracture loads of the specimen were measured by Instron universal testing machine. The mean values of fracture loads for the groups were statistically compared by Duncan's multiful range test. The result were as follows : Mean fracture strengths of each group were 86.95Mpa in no lingual extention group, 44.98Mpa in 0.5mm lingual extention group, 27.47Mpa in 1mm lingual extention group, 19.61Mpa in 2mm lingual extention group. There was a statistically significant difference between all group(p<0.01).
키워드