Effect of Linear Polarized Near-Infrared Ray Radiation on the Experimental Pain Threshold in Healthy Subjects

직선 편광 근적외선 조사가 건강인의 실험적 통증역치에 미치는 영향

  • Lee, Jae-Hyoung (Dept. of Physical Therapy, Wonkwang Public Health College) ;
  • Song, In-Young (Dept. of Physical Therapy, Wonkwang Public Health College) ;
  • Choi, Eun-Young (Dept. of Physical Therapy, Wonkwang University Medical Center)
  • 이재형 (원광보건전문대학 물리치료과) ;
  • 송인영 (원광보건전문대학 물리치료과) ;
  • 최은영 (원광대학교의료원 물리치료실)
  • Published : 1995.12.31

Abstract

The purpose of this study was to determine the effects of linear polarized near-infrared ray radiation on experimental pain threshold in healthy adult subjects. Thirty healthy adult subjects were divided into 5 groups: 1) group 1, super lizer radiation at 0 % ; 2) group 2, super lizer radiation at 10 % ; 3) group 3, super lizer radiation at 20 % ; 4) group 4, super lizer radiation at 40 % ; 5) group 5, super lizer radiation at 80 %. The polarized near-infrared ray radiation was applied on LI 4 point of subject's right hand at a fixed time for 30 second. Experimental pain threshold were measured with electrical current on the right hand at 5 intervals for each radiation: 1) pretreat; 2) posttreat ; 3) posttreat of 1/2 hr ; 4) posttreat of 1 hr ; and 5) posttreat of 2 hrs. Data were analyzed using analyses of variance with repeated measures for pain threshold. No significant interaction between power output and time for pain threshold was found. Significant effects of power output and time for experimental pain threshold were found. Significant increase was noted in experimental pain threshold in group 4 and group 5 at posttreat, posttreat of 1/2, 1 hr and 2 hrs as a result of the applications of the polarized near-infrared ray radiation. This study indicate that polarized near-infrared ray radiation with above 40 % of power output increases pain threshold, thus possibly increasing options in choosing radiation output for treating pateint with pain. Further study is needed to compare the effects of these radiation in patients with clinical pain.

편광 근적외선 조사가 실험적 통증역치에 영향을 미치는지를 규명하기 위해서 건강한 성인의 합곡혈에 여러 단계의 출력량으로 편광 근적외선을 30초간 조사하고 시간 경과에 따라 실험적 통증역치를 측정하여 분석하였다. 실험 결과 출력량 0 %인 대조군과 10 % 및 20 %의 출력량에서는 실험적 통증역치의 유의한 변화가 없었다. 그러나 출력량 40 %군의 실험적 통증역치는 편광 근적외선 조사전 $3.85{\pm}0.51mA$에서 조사 직후 $4.77{\pm}0.87mA$, 조사 후 30분 $5.57{\pm}0.98mA$, 조사 후 1시간 $5.68{\pm}1.06mA$, 조사 후 2시간 $5.34{\pm}0.96mA$로 증가되었고, 출력량 80 %군에서도 실험적 통증역치가 조사전 $3.87{\pm}0.92mA$에서 조사 직후 $4.45{\pm}0.62mA$, 조사 후 30분 $4.91{\pm}0.51mA$, 조사 후 1시간 $4.93{\pm}0.62mA$, 조사 후 2시간 $5.55{\pm}1.11mA$로 증가하였다. 실험적 통증역치는 편광 근적외선 조사 직후부터 2시간까지 유의하게 증가하였다. 40 % 출력량과 80 % 출력량의 실험적 통증역치는 유의한 차이가 없었고, 출력량과 시간의 상호작용효과는 없었다. 건강인의 실험적 통증역치를 대상으로 한 본 연구 결과를 통증이 있는 환자에게 직접 적용하기는 어렵다고 생각하며 앞으로 환자를 대상으로한 연구가 수행되기를 기대한다.

Keywords