Journal of environmental and Sanitary engineering (환경위생공학)
- Volume 10 Issue 2
- /
- Pages.79-88
- /
- 1995
- /
- 2005-5889(pISSN)
A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge
코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구
Abstract
The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.