24 Pulse Current Source Inverter For Reducing the Harmonics in Output Currents

출력전류의 고조파 저감을 위한 24펄스 전류형 인버어터

  • 유철로 (전북대 공대 전기공학과) ;
  • 이공희 (전주공업전문대 전기과) ;
  • 이성룡 (군산대 공대 제어계측공학과) ;
  • 한우용 (전북대 대학원 전기공학과)
  • Published : 1992.01.01

Abstract

A 24 pulse current source inverter for reducing the harmonics in output currents is presented in this paper. The proposed system operates a 24 pulse inverter by adding only tap changing circuit which consists of several taps and static switching elements to the 12 pulse inverter, which is the double connected 3 phase 6 pulse inverter with an auto transfomer. Also to optimize the effectiveness of the harmonic reduction, the optimum turn ratio and tap changing control angle of auto transfomer are decided by digital simulation and its validity is verified with experiment. And under the optimum condition, it is clarified that the harmonics components involved in the output current of the proposed inverter are nearly equal to those of the conventional 24 pulse inverter.

Keywords