Acknowledgement
Supported by : 한국과학재단
The objective of this study was to develop automatic systems of nutrient solution management for optimal nutrient solution environment and labor saving in water culture which enables factory crop production. In this study, an automatic control system and its driving program are developed to prepare, supply, and recover nutrient solution and to keep the optimal solution concentration level using microcomputers. Based on this study, the following conclusions are obtained: 1. The concentration measured by the system using oscillating circuit designed and built in this study, gave good agreements with the actual nutrient solution. 2. In water culture, the period of 12 hours for measuring concentration, pH, and temperature of the nutrient solution was optimum. Addition of control solution due to the decrease of the nutrient solution concentration is required in every 3 to 5 days. 3. It is estimated that the period of the whole solution change is 15 days, however, further research is needed to assure it. In addition, this period must be shortened in the future. 4. Both the hardware and software of the developed optimal nutrient solution control system in the water culture are working very well, however, it is necessary to develop a more economical one-chip micro controller to substitute for the microcomputer.