An experimental study on the marginal fitness of the full cast crown

전부주조금관의 치경부변연의 적합도에 관한 실험적연구

  • Cho, Sung-Am (Dept. of Prosthodontics, Graduate School, Seoul National University)
  • 조성암 (서울대학교 대학원 치의학과 보철학)
  • Published : 1982.12.01

Abstract

The purpose of this study was to compare the marginal fitness between Ni-Cr alloy and type III gold alloy, according to two finishing line, chamfer and shoulder. As experimental materials, author selected type III gold alloy and Ni-Cr alloy (Hicrown) which were popularly used in Korea for the full cast crown. Author prepared the wax patterns with milled stainless steel die and ring. The wax patterns were invested, burnouted, and casted. The maginal discrepancy was measured with scanning electron microscope. Author obtained the following results from this study. 1. The maginal fitness of Type III gold alloy was not significantly different from that of Ni-Cr alloy (Hi-crown). 2. There is no significant difference between chamfer and shoulder in case of Type III gold alloy. 3. The maginal fitness of chamfer type is significantly superior to that of shoulder type in the Ni-Cr alloy (Hi-Crown).

Keywords