치과 X선발생장치 및 방어에 관한 조사연구

A LIMITED SURVEY OF DENTAL X-RAY UNITS AND PROTECTION IN KOREA

  • 박태원 (서울대학교 치과대학 치과방사선학교실)
  • Park T.W. (Dept. of Oral Radiology, College of Dentistry, S.N.U.)
  • 발행 : 1980.12.01

초록

In dental roentgenograph it is of mutual benefit to the patient and the dentist to use the minimum amount of radiation capable of producing roentgenograms with maximum interprtive informations. Recent increases in the number of diagnostic x-ray examinations made in this country have caused attention to be paid to the quantity of radiation delivered to the population and operator. The purposes of this study was to assess the quality of dental x-ray units, the amount of films, the average processing procedures and the radiation protection methods in korea. The results were as following: 1. Most of radiation generating system were used in low voltage such as 60Kvp, 10㎃. 2. High sensitivity films such as 'D' group of Kodak or Rinn were mainly used and average 14.7 films used per weeks. 3. Some dentists practiced visual processing technic in simple dark room, and others used instant films. 4. 68.26% of patient held the film themselves, but 27.30% were assisted by dentists film holding. 5. In radiation protection method, 7.85% of dentists had protection equipments such as protective barrier, 2.73% wore protective apron, 27.9% made it a rules to avoid beam, and 7.51% used to maintain a distance from the radiation source.