대한기계학회논문집 (Transactions of the Korean Society of Mechanical Engineers)
- 제2권1호
- /
- Pages.10-18
- /
- 1978
- /
- 1225-5963(pISSN)
DOI QR Code
Notch재 피로와 Kikukawa-Compliance법 (제 1 보 기초적 검토)
Notched Specimen Fatigue and Kikukawa's Compliance Technique(Part I.On Some Basic Testing Results)
- ;
- ;
- Park, Yung Jo
- 발행 : 1978.02.01
초록
Kikukawa's compliance method using the conventional crack mouth clip-on gauge was proposed as a desired measurement technique to monitor the notched specimen fatigue behavior. The measurement technique makes it possible to continuously monitor the initiation and growth of incipient small part-through crack originated at the notch root and the phenomenon of crack closure. The variarion of natural flaw geometry with fatigue cycling was investigated. The test results on 7075-T6 aluminium alloy suggest the dependence of effective stress intensity factor range ratio .upsilon. on the maximum stress intensity factor .KAPPA.max.
키워드