Asessment of Fire Damage Depth of 21MPa-class Concrete Using Thermogravimetric Analysis

열중량분석을 활용한 21MPa급 콘크리트의 화해피해깊이 진단방법 분석

  • 임군수 (청주대학교 건축공학과) ;
  • 한수환 (청주대학교 건축공학과) ;
  • 한준희 (청주대학교 건축공학과) ;
  • 윤치환 (청주대학교 건축공학과) ;
  • 한민철 (청주대학교 건축공학과) ;
  • 한천구 (청주대학교 건축공학과)
  • Published : 2021.05.20

Abstract

In this study, we develop diagnostic technology for damage depth of fire-damaged concrete and propose methods for damage caused by fire by drying damaged concrete after immersion. As a result of the test, the damaged depth was clearly found when evaluating the depth of impurities caused by fire in a drying method after water had permeated, and it could be verified using thermogravimetric analysis.