Assesment of Impaired Depth due to Fire of Mock-up Concrete with 40MPa Using Drying Method After Water Immersion
수중 침지 건조방법을 이용한 40MPa Mock-up부재의 화해피해 깊이진단
Abstract
In this study, we develop the damage depth diagnostic technology of fire damage concrete and propose an method of impaired depth due to fire by drying impaired concrete after immersing. Test results indicated that when assesing impared depth due to fire with the dry method after water immersing, impaired depth was clearly found and furthermore, compared with that by Phenolphthalein method 15 mm of damage depth was additionally identified, which is imposible to asses when Phenolphthalein is applied.
Keywords