Setting Analysis of Super Retarding Agent according to Curing Temperatur

양생온도 변화에 따른 초지연제의 응결지연 성능 변화 분석

  • 현승용 (청주대학교 건축공학과) ;
  • 임군수 (청주대학교 건축공학과) ;
  • 한수환 (청주대학교 건축공학과) ;
  • 김종 (제주대학교 건축공학과) ;
  • 한민철 (청주대학교 건축공학과) ;
  • 한천구 (청주대학교 건축공학과)
  • Published : 2020.11.12

Abstract

This research is part of the research for unifying the mass concrete and utilizing the rate of super retarding agent. We analyzed the performance of super retarding agent under low temperature conditions. It was found that there was no deterioration in fluidity and air quality due to the change in the super retarding agent mixing rate. It was found that when super retarding agent was mixed up to 0.5 %, it was delayed for 22.3 hours at 20℃, 48.2 hours at 10℃, and 48.5 hours at 5℃. Therefore in order to ensure the performance required at the site, the super retarding agent mixing rate must be determined by fully considering the situation at the site. In addition it will be analyzed that super retarding agent performance analysis at high temperature will be required in subsequent studies.

Keywords