기존 건축물 층간소음 저감공법 적용 효과 분석

A Effects of applying the noise reduction method between existing buildings

  • 송태협 (한국건설기술연구원 건축도시연구소) ;
  • 전찬수 (한국건설기술연구원 건축도시연구소) ;
  • 김지훈 (한국건설기술연구원 건축도시연구소)
  • 발행 : 2018.05.16

초록

To control the floor noise generated in the apartment building, a method of reinforcing the floor at the floor is applied. However, since existing buildings are difficult to reinforce upper generations, the ceilings of lower generations should be reinforced. The purpose of this study is to analyze the reduction effect by measuring the impact noise after reinforcing the floor soundproofing material on the ceiling of the existing building. In order to ensure the economical efficiency and flame retardancy of the products used as building interior materials, the existing polyurethane foam was impregnated with mineral to prepare test specimens and attached to the concrete slab surface. As a result, it was shown that heavy impact sound can reduce 2dB~5dB and light impact sound can reduce 4~8dB.

키워드