The study on Response of the Sensor for monitoring of Chloride Penetration in Concrete

콘크리트내 비래 염소이온 침투 모니터링을 위한 부식센서의 응답성능 평가에 관한 연구

  • 신상헌 (한양대학교 대학원 첨단건축도시환경공학과) ;
  • 이현석 (한양대학교 대학원 건축공학과) ;
  • 류화성 (한양대학교 대학원 건축공학과) ;
  • 김보석 (한양대학교 대학원 첨단건축도시환경공학과) ;
  • 이한승 (한양대학교 ERICA캠퍼스 건축학부)
  • Published : 2014.05.29

Abstract

The study is used to verify the applicability of the sensor to monitor penetration of chloride into the concrete, like real coastal environment. After manufacturing the specimen adapt corrosion sensor for chloride penetration monitoring, chloride spray experiment was conducted. And then, It was checked the possibility of monitoring of the penetrated chloride by measuring the resistance of the corrosion sensor that was embedded in each depth of the concrete. Experimental results, it is confirmed that the corrosion resistance of the sensor was increased depending on the concentration of chloride. Therefore, it is estimated that the sensor is available for monitoring of chloride penetration.