Proceedings of the Korean Institute of Building Construction Conference (한국건축시공학회:학술대회논문집)
- 2013.05a
- /
- Pages.323-325
- /
- 2013
A Study on the fire resistance for explosive spalling according to two side
폭렬에 기인한 2면 내화가열실험에 관한 연구
- Lee, Kyu Min ;
- Kang, Seung Goo ;
- Kim, Dong Jun ;
- Lee, Jae Young ;
- Harada, Kazunori ;
- Kwon, Young Jin
- 이규민 (호서대학교 소방방재학과) ;
- 강승구 (호서대학교 소방방재학과) ;
- 김동준 (호서대학교 소방방재학과) ;
- 이재영 (교토대학 건축공학과) ;
- 原 (교토대학 건축공학과) ;
- 田和典권영진 (호서대학교 소방방재학과)
- Published : 2013.05.09
Abstract
This study on the proposes a spalling mechanism based on the results of a fire resistance test of HSC(High Strength Concrete) considering important factors of spalling occurrence. The factors considered in this two-sided are fire resistance test to ISO 834 fire curve. In this study, explosive spalling phenomena in the specimens were investigation.
Keywords