Analysis on the Induction Effects by Separation Distance between the Power Feeding Station and the Telecommunication Cables

고속전철 급전소와의 이격거리에 따른 전력 유도 영향 분석

  • Choi, Mun-hwan (ETRI(Electronics and Telecommunications Research Institute)) ;
  • Lee, Snag-mu (ETRI(Electronics and Telecommunications Research Institute)) ;
  • Cho, Pyung-dong (ETRI(Electronics and Telecommunications Research Institute))
  • Published : 2012.10.26

Abstract

We have analyzed the induction effects by separation distance between the power feeding station and the telecommunication cables. To do this we measured the induced voltage in 11 sections(10km) between Jangseong and Imgok at Jeon-nam province using telecommunication cable installed nearby KTX's feeder line. Sub-section has about 1km length of telecommunication cable. And we used normalization method in installed length of telecommunication cables and mutual inductance to analysis the induction effects more rationally.

고속 전철의 전력 공급 시설인 급전소와의 이격거리에 따른 전력 유도의 영향을 분석하기 위하여 전남 장성과 임곡간 10km 구간에 대하여 1km의 단위 구간으로 분할하여 통신 케이블을 고속 전철 선로와 인접하여 병행 포설한 후 고속 전철이 통과하는 시간 동안의 유도 종전압을 측정하고 이를 분석하였다. 정확한 분석을 위하여 지형적 특성 상 1km 단위의 구간 분할이 어려운 개소에서 측정된 유도 전압에 대하여 1km 구간으로 정규화 하였으며 또한 각 개소에서의 대저저항률 및 통신선과 전차선간 이격거리를 이용하여 계산되는 상호인덕턴스 역시 임의의 기준 값으로 정규화 하여 분석을 수행하였다.

Keywords