The Consideration in Terms of Pressure Probe Used in Experiments of Supersonic Wind Tunne II

초음속풍동 실험에서 사용하는 압력측정 Probe에 대한 고찰 II

  • 이재호 (현대로템 추진연구팀) ;
  • 이영빈 (서울대학교 기계항공공학부) ;
  • 최중근 (서울대학교 기계항공공학부) ;
  • 최종호 (국방과학연구소 1기술연구본부 5부) ;
  • 윤현걸 (국방과학연구소 1기술연구본부 5부) ;
  • 김규홍 (서울대학교 기계항공공학부)
  • Published : 2011.11.24

Abstract

In this paper, the characteristic of pressures had been analyzed with a series of shapes that are pressure probes used in supersonic wind tunnel. When a performance of supersonic wind tunnel is evaluated, the Mach number is calculated by using the ratio of static pressure in test section wall to total pressure in settling chamber. Also the flow condition can be visualized by schlieren system. However a number of limitations exist to measure pressure of test section due to high speed and boundary layer effect. Therefore a specific pressure probe is needed for evaluating flow condition in test section at a various of positions. In the paper, experiments were conducted in terms of some pitot probes and the results were compared and analyzed.

초음속풍동에서 사용하는 압력 probe의 형상에 따른 압력특성에 대하여 분석하였다. 초음속풍동의 성능을 평가할 때 시험부의 벽면정압력과 전방안정실의 전압력을 측정하고 그 비로 마하수를 계산한다. 또한 쉴리렌 가시화를 통하여 유질의 상태를 확인한다. 그러나 매우 빠른 초음속 영역에서는 경계층의 영향을 무시할 수 없기 때문에 시험부의 압력을 측정하는데 한계가 있다. 따라서 시험부의 유질이 균일한지 확인을 위해 다양한 위치에서 압력을 측정하기 위한 probe가 필요하다. 본 논문에서 몇 가지 피토형상에 대해서 실험을 진행했고, 그 결과를 비교 분석했다.

Keywords