Water-flow Test/Performance Evaluation of Nonimpinging-type Injector used in the Hydrazine Thruster of Medium-level Thrust

중형급 하이드라진 추력기에 장착되는 비충돌형 인젝터의 수류시험 및 성능평가

  • 정훈 (부경대학교 대학원 에너지시스템공학과) ;
  • 김종현 (부경대학교 기계공학과) ;
  • 김정수 (부경대학교 기계공학과) ;
  • 김인태 ((주)한화 대전사업장 개발부)
  • Published : 2011.11.24

Abstract

A water-flow test for acceptance verification is carried out for a nonimpinging-type injector prior to the design-performance verification of hydrazine thruster under development. The injector used in the experiment is to be equipped on the hydrazine thruster producing 70 N of nominal thrust at an inlet pressure of 24.6 $kg_f/cm^2$. It is observed that there exist varying characteristics of atomization among the injector-nozzle orifices caused by a fabrication error which can be judged from a microscopic standpoint. On the other hand, all of the injector orifices are placed within the design criteria in an injection-angle performance.

본 연구팀에서 개발 중인 하이드라진 추력기의 설계성능 검증에 앞서 요소부품인 비충돌형 인젝터에 대한 인수시험 및 수류시험을 수행하였다. 실험에 사용된 인젝터는 추진제 주입압력 24.6 $kg_f/cm^2$에서 70 N의 공칭추력을 내는 하이드라진 추력기에 장착되는 것이다. 각각의 인젝터 노즐 오리피스의 미세한 가공오차에 기인하여 미립화 특성 차이가 관찰되기는 하였으나, 인젝터 분사각 관련 성능평가에서는 모든 오리피스가 합격범위에 있음이 확인되었다.