Analytic Expectation of Carbonation Depth of Indoor Concrete According to CO2 Concentration

건축물 실내 CO2 농도 분포에 따른 콘크리트 탄산화 깊이 산정에 관한 연구

  • 박동천 (한국해양대학교 해양공간건축학과) ;
  • 박근석 (한국해양대학교 해양건축공학과) ;
  • 안재철 (동아대학교 건축공학과) ;
  • 강병희 (동아대학교 건축공학과)
  • Published : 2011.11.18

Abstract

Carbon dioxide in atmosphere causes concrete carbonation which is the phenomenon, that is, the pH of concrete changes from 12-13 to 8.85-10. Even though the carbon dioxide concentration of indoor is higher than that of outdoor, the micro measurement has not carried out. The concentration of carbon dioxide was measured in three places. The data was used as boundary condition to FEM analysis for expectation of concrete carbonation depth. The affect of building finish materials to concrete carbonation was discussed.

Keywords