Column Shortening Analysis and Field Measurement of Haeundae I'Park

초고층 건축물의 기둥축소량 해석 및 현장계측 - 해운대 아이파크

  • Published : 2011.05.20

Abstract

The effect of column shortening is a major consideration in design and construction of tall buildings, especially in concrete and composite structural systems. To avoid unexpected demage in structural and nonstructural elements, differential shortening between vertical members resulting from differing stress levels, loading histories, volume-to-surface ratios and other factors in a high-rise building must be properly considered in the design process. This paper represents analyzed and measured shortening results of RC cores and columns at the 72 story Haeundae I'Park. It shows that WACS program based on ACI and PCA material model is effective for the prediction of column shortening.

Keywords