The Analysis on Energy Performance according to Characteristics of Glazing in High-rise Office Buildings
Glazing 특성에 따른 고층 오피스 건물의 에너지성능 분석
- Hwang, Woo-Jin (Jasanglass, Glazing Desing Lab) ;
- Kim, Kyo-Joon (Jasanglass, Glazing Desing Lab) ;
- Choi, Won-Ki (Jasanglass, Glazing Desing Lab)
- Published : 2011.04.07
Abstract
In case of newly constructed buildings, the construction type is almost Curtain-wall system or large window in building skin. However, these kind of buildings have problems with regulations on building energy efficiency. And national regulations on building energy efficiency limit only the V-factor of window(except infiltration), it is hard to predict energy consumption of Curtain-wall buildings which gain large solar energy in summer. In this study, the influence of LSG(Light to Solar Gain) on energy performance was theoretically analyzed with simulation. LSG is the value of VLT divide SHGC and represents the optical performance of the glass or glazing. The Window & Therm program developed in LBNL was used to analyze window systems and EnergyPlus was used to building energy. Cases of glazing are three types; single coated Low-e clear glazing, tripple coated Low-e clear glazing, tripple coated Low-e tinted glazing. The results of this study are follows; 1) The building energy consumption of Alt-l, 2, 3 were about 300, 253,