액체식 PVT 복합모듈의 유형별 성능 비교 분석
The Experimental Performance Comparison of a Water Type Glazed and Unglazed PV-Thermal Combined Modules
- Kim, Jin-Hee (Dept. of Architectural Eng., Graduate School, Kongju National University) ;
- Kang, Jun-Gu (Dept. of Architectural Eng., Graduate School, Kongju National University) ;
- Kim, Jun-Tae (Dept. of Architectural Eng., Kongju National University)
- 발행 : 2009.06.25
초록
The excess heat that is generated from PV modules can be removed and converted into useful thermal energy. A photovoltaic-thermal(PVT) module is a combination of photovoltaic module with a solar thermal collector, forming one device that receives solar radiation and produces electricity and heat simultaneously. In general, two types of PVT can be classified: glass-covered PVT module, which produces high-temperature heat but has a slightly lower electrical yield, and uncovered PVT module, which produces relatively lower temperature heat but has a somewhat higher electrical performance. In this paper, the experimental performance of two types of the PVT combined module(water type), glazed(glass-covered) and unglazed, was analyzed. The electrical and thermal performance of the PVT combined modules were measured in outdoor conditions, and the results were compared.