A Study on Estimating Reduction of Heating Energy and CO2 by Indoor Setting Temperature with Clo
착의량별 실내설정온도에 따른 난방에너지 및 온실가스 저감량 산정 연구
- Yoon, Jong-Ho (Dept. of Architecture Engineering, Hanbat National University) ;
- Lee, Chul-Sung (Dept. of Architecture, Graduate School, Hanbat National University) ;
- Kim, Hyo-Jung (Dept. of Architecture, Graduate School, Hanbat National University) ;
- Park, Jae-Wan (Dept. of Architecture, Graduate School, Daejeon University) ;
- Shin, U-Chul (Dept. of Architecture Engineering, Daejeon University)
- Published : 2009.04.10
Abstract
The studies for mechanical performance development have been examined to reduce energy consumption in building construction field. However, The energy consumption using in building for heating is impacted by not only system performance but also PMV particularly at temperature and clo. Most energy using in building part is mainly consumed for heating and cooling to keep comfort temperature. Heating energy consumption is bigger than cooling energy in Korea because of temperature difference in winter in comparison with summer at apartment building. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study evaluate actual comfort temperature range by clo and examined heating energy consumption by Esp-r and CO2 reduction possibility. The results show that keeping ASHRAE standards can reduce heating energy up to 23%; also, wearing underclothes with ASHRAE standard can reduce heating energy up to 47.8%. Option 4 showing Maximum CO2 emission reduction indicates that kerosene. LNG and electricity can reduce 1.5t, 1.7t, 2.46t respectively in comparison with option 2.
Keywords