The steam turbine condenser pressure optimization with different heat rate correction curves

각기 다른 열소비율 보정곡선을 갖는 증기터빈의 최적 복수기 운전압력 설정

  • 조천환 (한국남동발전(주) 영흥화력본부) ;
  • 백남호 (한국남동발전(주) 영흥화력본부) ;
  • 허진혁 (한양대학교 대학원 기계공학과) ;
  • 이재헌 (한양대학교 대학원 기계공학과) ;
  • 문승재 (한양대학교 대학원 기계공학과) ;
  • 유호선 (숭실대학교 기계공학과)
  • Published : 2008.03.26

Abstract

The present study performs a test of a change in a condenser pressure on two kinds of power plants having different condenser pressure-heat rate correction curve and evaluates the results. According to a result of the test, it is confirmed that a sub-critical drum type steam power plant is optimally operated at the condenser pressure of 38㎜Hga that is designed, even during winters. On the other hand, it can be found that a supercritical once through type steam power plant operated at the condenser pressure that is reduced below a design value, that is, up to 28㎜Hga during winters is advantageous in view of turbine efficiency and is operated without a problem in facility operation such as moisture erosion, turbine vibration, etc. Also, the present study compares and reviews a condenser pressure-heat rate correction curve proposed by a manufacturer and a test value. The present study proposes optimum condenser operation pressure capable of concurrently satisfying the stable operation and efficiency improvement of the power plant facility that is operating, making it possible to support an efficient operation of a power plant.

Keywords