An evaluation of compressive lap splice of the D22 rebar by concrete strengths

콘크리트 강도변화에 따른 D22mm 철근의 압축이음 성능 평가

  • Published : 2008.04.24

Abstract

Column specimens were constructed with main parameters significantly affecting the strength of the compression lap splice, such as lap length, spacing of lapped bars, amount and location of transverse reinforcements, and concrete strength. An experimental study has been conducted with column specimens in concrete strength of 40 to 60 MPa. Diameters of lapped reinforcing bars are 22 mm. An axial load was monotonically applied to the column specimens. All specimens failed in a brittle sudden manner and cover concrete was blasted out at maximum load. Compression lap splice strengths of specimens were evaluated from strains measured at the beginning of the lap length. Effects of the main parameters on the strengths of compression lap splice are assessed. Similarly to strengths of tension lap slice, the compression splice strength is found to be affected by lap length, spacing of lapped bars, transverse reinforcements.

고강도 콘크리트의 적용 확대에 반해, 현행 철근의 정착 및 이음 산정식은 70MPa 미만의 콘크리트로 한정되어 있으며, 50MPa 이상에서는 압축이음길이가 인장이음보다 길어지는 현상이 발생하는 등 관련 기술이 미비한 상태이다. 본 연구에서는 고강도 콘크리트에서 콘크리트 압축강도, 철근간격, 직교방향 보강 철근의 위치와 보강량에 따른 철근 압축이음내력 특성을 평가하였다. 압축이음된 22mm 철근을 주근으로 가지는 총 64개의 기둥 실험체를 제작하여, 단조 일축 압축 하중을 파괴 시 까지 재하하여 실험을 수행하였다. 실험결과 콘크리트의 압축강도, 압축 이음 길이, 철근간격 및 직교방향 보강 철근 등이 철근의 압축이음 내력을 결정하는 주요한 요소로 작용하는 것으로 분석되었다.

Keywords