Generation of Hydration Heat of the Concrete Combined Coarse Particle cement and Fly ash
조분시멘트와 플라이애시를 조합 사용한 콘크리트의 수화발열 특성
Abstract
This study, having combined and displaced fly ash known as admixture material that delays hydration reaction with coarse particle cement("CC" hereinafter) collected in particle classification method during ordinary portland cement("OPC" hereinafter), reviewed the hydration heat characteristics affecting the concrete. To reduce hydration heat, the study plain-mixed which used 100% OPC for WB 50% level 1, displaced CC at level 3 of 25%, 50% and 75% for OPC, and by displacing FA with admixture material at level 5 of 0%, 10%, 20%, 30% and 40%, experimented totally 16 batches. As a result of experiment, in the case of flow, the more CC displacement rate increased, the more it tended to decrease, and the more FA displacement rate increased, the more it decreased. As for simple adiabatic temperature rise by the CC and FA displacement rates, it decreased as displacement rate increased, and particularly in the case of FA40, temperature rise amount,
본 연구는 보통포틀랜드 시멘트(이하 OPC)의 제조공정 중 입도 분급에 의해 포집된 조분시멘트(이하 CC)와 저발열 혼화재료인 플라이애시(이하 FA)를 조합 치환하여 콘크리트에 미치는 수화발열특성에 대해 검토하고자 하였다. 실험은 W/B 50% 1수준에 대하여 OPC를 100% 사용한 것을 Plain 배합으로 하고, CC를 OPC에 대하여 25, 50, 75%의 3수준으로 치환하고, 혼화재로 FA를 0, 10, 20, 30, 40%의 5수준으로 치환하여 총 16배치를 계획 하였다. 실험결과로 유동성의 경우는 CC 치환율이 증가할수록 점점 감소하는 경향을 나타냈고, FA의 치환율이 증가할수록 증가하였다. CC 및 FA 치환율 별간이단열에 의한 온도 상승량은 치환율이 증가할수록 감소하였는데, 특히 FA40의 경우 CC치환율에 관계없이 최대 피크온도가