A Study on Unbalanced Moment of Flat Plate Exterior Connections
플랫 플레이트 외부접합부의 불균형모멘트에 관한연구
- Published : 2008.04.24
Abstract
Flat plate slab has been widely used in high rise building for its remarkable advantages. However, Flat plate structures under lateral load are susceptible to punching shear of the slab-column connection. Exterior slab-column connections has an unsymmetrical critical section for eccentric shear of which perimeter is less than that of interior connection, and hence, around the connection, unbalanced moment and eccentric shear are developed by both gravity load and lateral loads. Therefore, exterior connections is susceptible to punching shear failure. For that reason, this study compare ACI 318-05 to CEB-FIP MC 90 that is based on experiment results and existing data of flat plate exterior connections. This study shows that compared to CEB-FIP MC 90 is more exact about eccentric shear stress, unbalanced moment and Both of all are not suitable in large column aspect ratio. Considering gravity shear ratio, These are suitable but design condition only consider gravity shear ratio. So these should be considered differences from change of design condition
플랫 플레이트 구조는 다른 구조형식에 비하여 매우 경제적인 구조형식이다. 그러나 횡하중을 받는 플랫 플레이트 구조는 슬래브-기둥 접합부의 뚫림전단파괴에 대해 취약하다. 플랫 플레이트 구조의 외부접합부는 편심전단에 대해 비대칭형의 위험단면을 가지고 있으며, 위험단면의 길이가 내부접합부 보다 작고 중력하중과 횡하중 모두에 의해 편심전다응력이 발생하게 되므로 뚫림전단파괴에 대해 매우 취약하다. 이에 본 논문에서는 플랫 플레이트 외부접합부의 실험결과와 기존 데이터를 바탕으로 ACI 318-05와 CEB-FIP MC 90의 설계기준식을 비교한 결과 편심전단응력, 불균형모멘트에 대해서 CEB-FIP식이 더 정확했고 형상비의 영향은 기둥 형상비가 큰 경우에는 기준식의 적용성에 문제가 있는 것으로 나타났다. 중력전단력비의 영향은 기준식의 제안을 만족하였으나 설계 기준에서는 단순히 중력전단비만 고려하고 있어서 다른 설계조건 변화에 따른 차이를 고려할 필요가 있다.
Keywords