The objective of this study offer the equation of the development length for GFRP reinforcement. Pullout test carried out to propose the development length for GFRP reinforcement. Test variables included embedment length (L=15, 30 and 45d$_b$ ), pure cover thickness(C=0.5, 1.0, 1.5, and 2.0d$_b$ ), diameter of reforcement(D10, D13 and D16), and three types, (domestic : K2KR, K3KR, foreign : AsUS) of GFRP reinforcement. The method of test were introduced pure pullout and tests lasted until the GFRP reinforcements were reached final failure. Based on the results through the pullout test, the bond characteristics and average bond stress for GFRP reinforcement were investigated. The equation of development length was proposed based on the regression analysis selected specimens having splitting failure. The equation gained from this study compared with the design equation provided by ACI committee 440.1R-06. The results through this study are capable of the flexural member design with GFRP reinforcement having lab spliced.

본 연구는 GFRP 보강근의 정착길이 산정식을 제안하는 것이다. 정착길이 산정식을 제안하기 위해 인발실험을 실시하였다. 실험변수는 묻힘길이, 피복두께, 보강근 직경, 보강근 종류이다. 묻힘길이는 15d$_b$, 30d$_b$, 45d$_b$로 하고, 순 피복두께는 0.5d$_b$, 1.0d$_b$, 1.5d$_b$, 및 2.0d$_b$로 계획하였다. 사용된 보강근은 모두 3종류(국내 2종, 국외 1종)이고 보강근 크기는 D10, D13, D16이다. 실험은 겹침이음된 GFRP 보강근 양 단부를 동시에 인발하여 최종파괴에 도달될 때까지 GFRP 보강근에 하중을 가력하였다. 인발실험을 통해 얻은 결과를 토대로 각 변수에 따른 GFRP 보강근의 부착특성 및 평균부착응력을 산정하였으며, 실험체중 쪼갬파괴된 실험체만을 선택하여 회귀분석을 통해 정착길이 산정식은 제안하였고 ACI 440.1R-06에 제안하고 있는 식과 비교하였다. 본 연구를 통해 제안된 회귀분석에 의한 제안식을 근거로 겹침이음된 GFRP 보강근을 이용한 휨 설계가 가능할 것으로 판단된다.