A number of structures constructed during past decades have suffered from safety and serviceability problems due to deterioration and many engineers have been increasingly concerned about durability of concrete. Pipe-cooling method has been popularly used in the massive concrete to reduce temperature of the structure. Until now, usually this pipe-cooling method was applied only in foundation concrete structures, but it is newly tried to apply in the wall structure. We analyzed thermal stress of wall structure with the general structural analysis program that will be able to express the pipe-cooling element. We studied about the effect of reducing temperature and cracking control in the wall structure which can be applied in a pipe-cooling method with the analytical result which follows in an arrangement of the cooling pipe.

최근 들어 구조물의 노후화에 따른 콘크리트 구조물의 내구성에 대한 관심이 증대되고 있고, 특히 초기재령에서 발생하는 온도응력에 의한 균열은 구조물 전체의 내구성에도 큰 영향을 미친다. 콘크리트구조물의 온도응력에 의한 균열을 제어하는 방법으로는 크게 재료 및 배합상의 방법, 설계상의 방법, 시공상의 방법으로 나눌 수 있다. 이 중에서 시공상의 방법 중 하나로 콘크리트 단면내의 온도 상승량을 감소시킬 수 있는 파이프쿨링 공법에 의한 사후냉각효과에 대해 연구를 진행하고자 한다. 지금까지 파이프쿨링 공법은 주로 기초등의 매스콘크리트에 많이 적용되었지만 새로이 벽체에도 적용하였고, 파이프쿨링 요소를 묘사할 수 있는 범용구조해석 프로그램을 이용하여 파이프쿨링 공법이 적용된 벽체구조물에 대한 온도응력해석을 수행하였다. 벽체 구조물에 쿨링 파이프의 배치에 따른 해석 결과를 바탕으로 파이프쿨링 공법의 벽체구조물에 대한 냉각효과 및 균열제어 효과를 알아보았다.