광CT 센서코일 끝단의 반사율이 전류측정에 미치는 영향

Effects of reflective index of fiber sensor coil end on current measurement

  • 발행 : 2008.05.08

초록

We improved an efficiency of fiber-optic current transformer by using a metal-coated sensor coil. To reduce the linear birefringence, we used a length of spun fiber as sensor coil, and then used a flint glass fiber coil for comparison. To make the sensor coil in the reflection type, we used different reflection mirrors at the end of the sensor coil, such as a Faraday rotator mirror, a simple mirror, a metal-coated fiber end and a simple fiber end. From the experimental results, the linear error of current measurements were less than ${\sim}$ 0.2 % regardless of the mirror types. The metal-coated sensor was the most cost-effective considering the fabrication cost and the simple structure.

키워드