Proceedings of the KSME Conference (대한기계학회:학술대회논문집)
- 2008.11b
- /
- Pages.2868-2873
- /
- 2008
Analysis of Mechanism for Diffusion of Incomplete Combustion Gas Released from Domestic Gas Boiler
가정용 보일러의 불완전연소가스 누출확산 메커니즘 해석
- Published : 2008.11.05
Abstract
Carbon Monoxide(CO) poisoning accident is higher than any other gas accident in the rate of deaths/incidents. In the last five years, 36 people died and 104 were wounded because of carbon monoxide poisoning accident. Most of these CO poisoning accidents were caused by defective exhaust tube in the old gas boiler and multi-use facility. In this study, the spread of incomplete combustion gas(CO) released from leakage hole of exhaust tube was analyzed by computational flow modeling and concentration measuring test. CO gas leaked form exhaust tube in a building was highest concentrated near the ceiling and formed the circular currents along the walls. Through these experiments and simulation, the reasonable installation location of carbon monoxide alarm was made certain and suggested.
Keywords