Proceedings of the KSME Conference (대한기계학회:학술대회논문집)
- 2007.05a
- /
- Pages.1792-1797
- /
- 2007
Root cause analysis on the phenomenon of voltage drop of connector used in the automotive throttle body control
스로틀 바디 제어신호 전달용 커넥터의 이상전압 강하 현상 원인 규명
- Published : 2007.05.30
Abstract
This paper try to find root-cause of failure in a connector used in transmitting signals for throttle body control in automotives by analyzing possible failure causes and performing experiments to simulate the cable failure in field. The connector comprises fins, wires, and case moldings. The failure is due to degradation of initial clamping force required fixing fins and wires in the connector. Expansion and compression of the case molding material surrounding fins would cause the degradation. Investigations of strict initial claming force and control of thermal expansion property of the molding are required to prevent the failure.
Keywords