Just noticeable difference of autocorrelation function (ACF) parameters of refrigerator noise

냉장고 소음 ACF 요소의 최소인지한계량 조사

  • 유진 (한양대학교 건축환경공학과) ;
  • 정충일 (한양대학교 건축환경공학과) ;
  • 전진용 (한양대학교 건축대학) ;
  • 조문재 (한국표준과학연구원 표준보급부 산업지원팀)
  • Published : 2007.11.15

Abstract

Just noticeable differences (jnds) of autocorrelation function (ACF) parameters - Phi (0), Tau 1 and Phi 1 - of household refrigerator noise were investigated by psychoacoustical analyses. Phi (0) of five refrigerators' noise was changed with equal (${\pm}$) interval level of 0.5-1.0 dB up to five intervals by manipulating sound pressure level of the noise. Tau 1 and Phi 1 were varied with equal (${\pm}$) interval of around 0.10 ms and 0.02, respectively. Pitch shifting and strengthen methods were applied for the Tau 1 and Phi 1 variations. As results of subjective evaluations, about 2.0 dB was shown as jnd of Phi (0). The values of 0.30 ms and 0.06 were found as jnds of Tau 1 and Phi 1, respectively. The jnd results of each ACF parameter can be applied to explain substantial amount of sound quality (SQ) enhancement in the SQ prediction indices which were proposed in the authors' previous study [Sato et al. (2007) J. Acoust. Soc. Am.].

Keywords