The Characterization of Spherical Particles in S/G Sludge

S/G 슬러지 중 구형입자의 특성측정

  • Published : 2005.06.01

Abstract

There should not be ion exchange resin particles in S/G sludge. The suspicious spherical resin particles observed in S/G sludge sample were characterized for particle size distribution under optical microscope using the micro-technique, for element analysis by the electron probe micro analysis (EPMA), and for molecular identification by the IR spectroscopy The particle sizes are distributed from 1 to 200 ${\mu}m$ for the sludge, while 40 to 500 ${\mu}m$ for the spherical resin particles. The results of the elemental analysis showed different major impurities: Si, Al, Mn, Cr, Ni, Zn and Ti for the sludge particles, while Si, Cu, Zn for the spherical resin particles. However, both particles contain Fe as a matrix of hematite ($Fe_{3}O_4$). IR spectrum of the spherical particles was quite different from that of ion exchange resins used in S/G system. These results indicate that the spherical particles are not related to ion exchange resin particles and formed by the process of the sludge formation.

원자력 발전소의 증기발생기 슬러지 중에서는 이온교환수지가 발견되어서는 안 된다. 증기발생기 슬러지 시료 중에서 발견되어 이온교환수지 입자로 의심되는 구형 입자들의 특성을 측정하였다. 미세조작기술을 이용하여 광학현미경으로 입자 크기 분포를, EPMA로 구형입자의 성분을, 그리고 IR 분광 스펙트럼 비교에 의하여 이온교환수지 여부를 조사하였다. 슬러지의 입자 크기는 1내지 200 ${\mu}m$이었으나 구형입자는 40-500 ${\mu}m$이었으며, 슬러지의 주요 불순원소가 Si, Al, Mn, Cr, Ni, Zn, 그리고 Ti이었으나 구형입자는 Si, Cu, Zn 이었다. 주성분은 두 경우 모두 철이었으며, IR 분광스펙트럼을 S/G 시스템에서 사용하는 이온교환수지의 경우와 비교했을 때 서로 다른 결과를 보였다. 이 결과들은 것은 증기발생기 슬러지 시료 중에서 발견된 구형 입자가 이온교환수지는 아니며 일반적인 슬러지가 생성되는 과정에서 작은 슬러지 입자들이 크게 뭉쳐서 생성된 것임을 나타내고 있다.

Keywords