Density Profile Measurement of Needle-punched Carbon/Carbon Nozzle Throat by the Analysis of Computed Tomography Image

전산화 단층촬영 영상 분석에 의한 탄소/탄소 목삽입재의 밀도 분포 측정

  • Published : 2005.11.01

Abstract

Tn this study, the noll-destructive computed X-ray tomography was adopted to observe the density distribution of the needle-punched C-C composites nozzle throat. The density distribution of the C-C was evaluated within ${\pm}0.01g/cm^3$ with 98.74% confidence when the correction of the image and high signal-to-noise ratio were achieved by the optimization of the beam hardening, the electrical noise and the scattered X-ray. The density variation of the C/C with the computed tomography was in good agreement with the results obtained by the water immersion method and the observation with scanning electron microscope.

전산화 단층촬영법을 이용하여 탄소/탄소 목삽입재의 밀도 분포를 평가 하였다. 전산화 단층촬영 법의 Beam hardening, 전기적 잡음 및 산란 X-ray의 영상을 토정하고 신호 대 잡음비를 높여 최적화할 때 측정된 제작된 탄소/탄소 복합재료의 밀도는 98.74%의 신뢰도 수준에서 ${\pm}0.01g/cm^3$ 분포를 갖는 것으로 평가 되었다. 전산화 단층촬영 결과의 검증은 탄소/탄소 목삽입재를 절단하며 수침법에 의한 밀도 측정과 주사전자현미경 관찰을 통하여 수행되었으며 단층촬영결과는 수침법에 의한 밀도 분포와 주사전자현미경의 결과와 일치하였다.