넙다리뼈 머리/목 부분 해면뼈의 기계적 물성

Mechanical Properties of Trabecular Bone in femoral Head & Neck

  • 곽대순 (가톨릭대 응용해부연구소) ;
  • 최광남 (한국과학기술정보연구원) ;
  • 김상국 (한국과학기술정보연구원) ;
  • 이상호 (한국과학기술정보연구원) ;
  • 김태중 (한국과학기술정보연구원) ;
  • 한승호 (가톨릭대 응용해부연구소) ;
  • 오택열 (경희대 테크노공학대학)
  • 발행 : 2005.10.01

초록

We performed the mechanical test for obtaining properties of femoral head. Tested sample was male and 35 years old. We measured bone mineral density by dual X-ray absorption method(DEXA). Results of DEXA, he has normal condition of bone density. His BMD $1.159g/cm^2$ and T-Score is 1.6. Tested femurs were harvested by surgical method from donated cadaver. We made 9 specimens in femoral head, 8 specimens in neck used by diamond core drill. Then we performed compressive test in saline solution at $38^{\circ}C$. We obtained results that elastic modulus of femoral head was 0.439GPa, neck was 0.459GPa. Compressive strength of femoral head was 7.441 MPa, neck was 7.095MPa. There was no significant difference of mechanical properties between left and right femoral head & neck. Invested local properties of femoral head have more strength superior and anterior side, femoral neck has more strength in superior and inferior side but other side except for superior has more weakness along the lateral side.

키워드