A Study on Strength of Flat Plate-Column Connections

플랫플레이트-기둥 접합부 강도발현에 관한 연구

  • 강수민 (대림산업(주) 기술연구소 건축연구지원팀) ;
  • 이도범 (대림산업(주) 기술연구소 건축연구지원팀) ;
  • 김욱종 (대림산업(주) 기술연구소 건축연구지원팀) ;
  • 이지웅 (대림산업(주) 기술연구소 건축연구지원팀) ;
  • 박홍근 (서울대학교 건축학과) ;
  • 이리형 (한양대학교 건축공학부)
  • Published : 2005.11.01

Abstract

A numerical analysis was performed for interior connections of continuous flat plate to analyze the effect of design parameters such as column section shape, gravity load and slab span on the behavioral characteristics of the connections. Through the parametric study, the variations of shear stress distribution around the connection were investigated. According to the result of numerical analysis, as the length of the cross section of column in the direction of lateral load increases and gravity load increases, the effective area and the maximum shear strength providing the torsional resistance decrease considerably. And as the slab span loaded with relatively large gravity load increases, the negative moment around the connection increases and therefore the strength of connection against unbalanced moment decreases.

Keywords