Evaluation Technique of Damaged Depth of Concrete Exposed at High Temperature

고온에 노출된 콘크리트의 손상깊이 추정기법

  • Published : 2005.11.01

Abstract

The purpose of this study is to investigate evaluation technique of damaged depth of concrete exposed at high temperature. In order to evaluate damaged depth of core picked at member under fire, the 12 specimens have been made with variables of concrete strength(20Mpa, 40Mpa, 60Mpa). Water absorption after heating has been measured and split tensile stress test was performed. The results show that the deeper of the depth from heating face, water absorption ratio is smaller and tensile failure stress is larger. Using this technique at damage evaluation of fired structure, We evaluate damaged depth of member under fire and determine the reasonable strengthening range.

Keywords