Analysis on the Behavior of Post-tensioned Precast Beam-Column Concrete Connectors

포스트텐션 프리캐스트 보-기둥 건식 콘크리트 접합부의 거동분석

  • 송형수 (동국대학교 토목환경공학과) ;
  • 유정욱 (동국대학교 건축공학과) ;
  • 김연수 (동국대학교 건축공학과) ;
  • 유승룡 (동국대학교 건축공학과)
  • Published : 2005.11.01

Abstract

Three precast concrete beam-column connectors for the high-rise office buildings were considered to investigate the prestressing effects of the DDC(Dywidag Ductile Connectors) of Germany and of the modified DDC. The specimens of DDC, DDC with post-tensioning and modified DDC with post-tensioning were constructed and tested to verify the safety. The DDC with and without post-tensioning showed reliable joint strength and ductility but failed in critical x-shape crackings at the column. The modified one showed better behaviors in tests because they did not show critical column crackings at failure. The use of prestressing did not helpful significantly to increase the strength and ductility of connectors but helpful only to develop self-centering behavior for stability.

Keywords