Design error corrector of binary data in holographic dnta storage system using fuzzy rules

근접 픽셀 에러 감소를 위한 홀로그래픽 데이터 스토리지 시스템의 퍼지 규칙 생성

  • Kim Jang-hyun (Department of Electronic Engineering, CISD. TONSEI University) ;
  • Kim Sang-hoon (Department of Mechanical Engineering, CISD. TONSEI University) ;
  • Yang Hyun-seok (Department of Mechanical Engineering, CISD. TONSEI University) ;
  • Park Jin-bae (Department of Electronic Engineering, CISD. TONSEI University) ;
  • Park Young-Pil (Department of Mechanical Engineering, CISD. TONSEI University)
  • Published : 2005.10.01

Abstract

Data storage related with writing and retrieving requires high storage capacity, fast transfer rate and less access time. Today any data storage system cannot satisfy these conditions, however holographic data storage system can perform faster data transfer rate because it is a page oriented memory system using volume hologram in writing and retrieving data. System can be constructed without mechanical actuating part therefore fast data transfer rate and high storage capacity about $1Tb/cm^3$ can be realized. In this paper, to reduce errors of binary data stored in holographic data storage system, a new method for bit error reduction is suggested. First, find cluster centers using subtractive clustering algorithm then reduce intensities of pixels around cluster centers and fuzzy rules. Therefore, By using this error reduction method following results are obtained ; the effect of Inter Pixel Interference noise is decreased and the intensity profile of data page becomes uniform therefore the better data storage system can be constructed.

Keywords