Fire Resistance of High Strength Concrete with Polypropylene and Vinylon Fiber

폴리프로필렌 및 비닐론 섬유를 혼입한 고강도콘크리트의 내화특성

  • 남지현 (동의대학교 건축공학과 대학원) ;
  • 오상균 (동의대학교 건축공학과) ;
  • 김정길 (동의대학교 건축공학과)
  • Published : 2005.05.01

Abstract

The fire damage of building wouid effect on the safety of structure. When the reinforced concrete structure is heated by high temperature due to the fire, the structural resisting-force will be decreased. In a way, it is a requirement to use high strength concrete for high rise building. Particularly, fire resistance properties of high-strength concrete is more important than normal strength concretes. The fire outbreak of a high strength concrete by sudden temperature rise is a main problem, and causes crack by thermal stress, loading to the deterioration of the durability. In this study, normal and high strength mortar were exposed to a high temperature environment. And than fundamental data for the character change of concrete heated highly were presented by measuring compressive strength of concrete with polypropylene and vinylon fiber, before and after heating. As the results, it is proven that high strength mortar with polypropylene and vinylon fiber for prevents deterioration of durability by fiber.

Keywords