Reinforced Earth Retaining Wall of The Collapsed-A Case Study.

보강토옹벽의 사고사례에 관한 연구

  • 유충식 (성균관대학교 토목공학과) ;
  • 정혁상 (성균관대학교 토목공학과) ;
  • 이성우 (성균관대학교 토목공학과)
  • Published : 2004.03.25

Abstract

This paper deal with cause and analysis about case of collapsed reinforced-soil retaining wall. The analysis of the cause was carried through experimentation, slop stability analysis and literature study. The experimentation treated the large direct shear test, the hydraulic conductivity test and the other basic test through backfill extracted from collapsed reinforced-soil retaining wall. The ultimate tensile strength was established by rib tensile strength test of geogrid. The analysis of internal and external stability of reinforced-soil retaining wall was performed on the basis of parameters. The result of analysis, reinforced-soil retaining wall and the slope at the dry season are stable. However, the factors that fine-grained soil at hydrometer test exceed the standard of the design, rainfall duration is too long at the time of collapse and monthly pricipitation is heavy are cause of the collapse.

Keywords