Reduction of noise and vibration of cabin by using the floating floor

뜬바닥 구조를 이용한 격실의 소음 및 진동저감

  • Published : 2004.05.01

Abstract

In this paper, floor impact noise reduction in a cruise ship cabin by using floating floor is studied. A mock-up is built by using 61 steel plate, and two identical cabins are made where 25t panel is used to construct wall and ceiling inside the steel structure. Various floating floor systems are tested for which normalized impact noise is measured according to ISO 140-7 It is shown that effect of VL(Visco-elastic Layer) is negligible when it is used between deck and mineral wool, since most vibration absorption occurs in the wool. In addition, direction of the mineral wool fiber affects impact noise significantly.

Keywords