원전 격납건물 돔 텐던의 축대칭 근사화에 대한 타당성 고찰

Verification for Axisymmetric Modeling of Dome Tendons in Nuclear Containment Building

  • 전세진 (대우건설기술연구소 토목연구팀) ;
  • 정철헌 (단국대학교 토목환경공학과) ;
  • 김영진 (대우건설기술연구소 토목연구팀) ;
  • 정연석 (한국원자력안전기술원 원자력안전연구실)
  • 발행 : 2004.11.01

초록

Prestressing tendons in a nuclear containment building dome are non-axisymmetrically arranged in most cases. However, simple axisymmetric modeling of the containment has been often employed in practice, which requires the axisymmetric approximation of the actual tendon arrangements in the dome. A procedure was previously proposed that can implement the actual 3D tendon stiffness and prestressing effect into the axisymmetric model for CANDU type. This paper further verifies and compares some methodologies adopted in the proposed scheme through some numerical examples.

키워드