Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2004.05a
- /
- Pages.420-422
- /
- 2004
Shaking Table Tests of the 1/3 Scaled R/C Building with the Laminated Rubber Bearings
적층고무형 면진장치를 갖는 RC건물의 면진효과 검증 진동대 실험
- Published : 2004.05.01
Abstract
This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by Dongil Rubber Belt Co.. The shaking table tests were performed using a scaled 3-story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Through the verification tests, the validity of the applied base isolation device and the response reduction effect against earthquakes are confirmed.
Keywords