Shaking Table Tests of the 1/3 Scaled R/C Building with the Laminated Rubber Bearings

적층고무형 면진장치를 갖는 RC건물의 면진효과 검증 진동대 실험

  • 김동영 (동일고무벨트(주) 기술연구소) ;
  • 천영수 (대한주택공사 주택도시연구원) ;
  • 황기태 (아키니어링) ;
  • 장극관 (서울산업대학교 건축공학과)
  • Published : 2004.05.01

Abstract

This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by Dongil Rubber Belt Co.. The shaking table tests were performed using a scaled 3-story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Through the verification tests, the validity of the applied base isolation device and the response reduction effect against earthquakes are confirmed.