Evaluation of horizontal shear strength of the shear connectors between precast decks and PSC girders

프리캐스트 바닥판과 PSC 거더 전단연결재의 수평전단강도 평가

  • Published : 2004.05.01

Abstract

A new shear connection for the application of precast decks to PSC girders was proposed and push-off tests were conducted to evaluate the horizontal shear strength of the shear connection. Major parameters of the tests were connector type, shank area, vertical load, surface condition and bedding height. Judging from the test results, shear strength of the suggested shear connection was proportional to the shank area and yield strength of the connectors and was in inverse proportion to the bedding height. Shear connection with shear key at the surface showed better performance. An empirical equation for the evaluation of the shear strength of the shear connection without considering bond strength was proposed and it showed good correlation with the test results.

Keywords