Proceedings of the Korea Concrete Institute Conference (한국콘크리트학회:학술대회논문집)
- 2004.05a
- /
- Pages.112-115
- /
- 2004
Evaluate Bond strength of high Relative Rib Area Bars Using Beam-end test specimens
보 단부 부착시험체에 의한 높은마디 철근의 부착성능
- Published : 2004.05.01
Abstract
Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force has a limitation. Thus, the only variable is the bearing angle corresponding to the change of bond force. Higher rib height bars possessing higher shearing resistance can maintain higher bearing angle and higher splitting resistance when bars are highly confined, and consequently higher bond strength, than lower rib higher bars. In this study, from the evaluate bond strength of high Relative Rib Area Bars Using beam-end test specimens are compared with the current provisions for development of reinforcement, and the improved design method of bond strength is proposed.
Keywords