An Analysis on Thermal Stratification in Residual Heat Removal System Piping of Nuclear Power Plant

가동원전 잔열제거계통 배관에서의 열성층유동 해석

  • 박만홍 (한국전력기술(주) 연구소) ;
  • 김광추 (한국전력기술(주) 연구소) ;
  • 김경훈 (경희대학교 기계산업시스템공학부)
  • Published : 2003.04.23

Abstract

Numerical analysis is carried out to assess the temperature distribution on the mixing tee line of Residual Heat Removal System (RHRS). In RHRS, hot and cold fluids of main and bypass piping are mixed and unmixed by the flow rate or piping layout. Thermal stratification phenomenon is a cause of major degradation on RHRS piping. According to the analysis for each operation modes, maximum temperature difference between top and bottom of piping were evaluated about 60K when the flow rate of main and bypass lines is same. Temperature difference will be decreased at the elbow on RHRS piping if the length of vertical piping is increased.

Keywords