화력발전소 주배관 3차원 변위측정시스템 개발

Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant

  • 송기욱 (한국전력공사 전력연구원 발전연구실) ;
  • 현중섭 (한국전력공사 전력연구원 발전연구실) ;
  • 하정수 (한국전력공사 전력연구원 발전연구실) ;
  • 조선영 ((주) K.R. 정밀)
  • 발행 : 2003.11.05

초록

Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

키워드